Description
Dead ended seal chamber with no flush fluid circulation.
Features
- Applicable to low seal chamber pressure and process temperature.
- Can be used with tapered seal chambers, especially for slurries.
- Normally is used along with a jacketed seal chamber.
Use
- In cool clean fluids with high specific heat, such as water, in relatively low speed pumps.
Caution
- To avoid flashing, process fluid temperature must be taken into consideration.
- Avoid use without cooling / heating jacket (for cylindrical chambers).
- Ensure top point vent in throat bush (for cylindrical chambers in horizontal pumps).